Free connection of digital signals
Free configuration of digital outputs
10
Function library
10.13
10.13.2
L
10.13-9
EDS82EV903-1.0-11/2002
Code IMPORTANTPossible settings
No. SelectionLenzeName
C0415
Possible d igital sign als for C0415
^
v
AIF control word (AIF-CTRL)
Assigned bits of AIF-CTRL:
10.13-1
(cont.)
40 Bit 0
Bit 3: QSP
... ...
Bit 7:
INH
Bit 10: TRIP-SET
55 Bit 15
-
Bit 11: TRIP-RESET
CAN-IN1.W1 or FIF-IN.W1
60 Bit 0
... ...
75 Bit 15
CAN-IN1.W2 or FIF-IN.W2
80 Bit 0
... ...
95 Bit 15
CAN-IN2.W1
100 Bit 0
... ...
115 Bit 15
CAN-IN2.W2
120 Bit 0
... ...
135 Bit 15
Status application I/O
Only active when using application I/O
140 Torque threshold 1 reached (MSET1=MOUT)
141 Torque threshold 2 reached (MSET2=MOUT)
142 Process controller output limit reached
(PCTRL1-LIM)
143...172 Reserved
255 Not assigned (FIXED-FREE)
C0409
Configuration relay
Output of digital signals to relay K2
• Relay output K 2 only with 8200 vector
^
v
output K2
255 255 Not assigned (FIXED-FREE)
15 ... 90
W
• F
r
r
i
nwi
h
li
i
n-I
nl
10.13-6
Digital signals p os s ible for C0409 s ee C0415
-
active as of version E82ZAFA...XXVx2x
C0416
v
Level inversion of
digital outputs
0
0 Level inversion is switched off By entering the sum of the selected values
you can invert several outputs
^
10.13-6
1 Relay K1
2 X3/A1
4 X3/A2 only application I/O
8 Relay K2 Relay output K2 o nly with 8200 vector 15
... 90 kW
C0423*
(A)
Digital output delay
0.000 {0.001 s} 65.000 ”Debouncing” of digital outputs
(as of version application-I/O E82ZAFA ...
^
10.13-6
1 Relay output K1
(RELAY)
0.000
Vx11)
• Switches t he digital output if the linked
2 Digital output
X3/A1 (DIGOUT1)
0.000
signal is still active after t he time set.
• Digital output reset without delay
3 Digital output
X3/A2 (DIGOUT2)
0.000
The digital outputs are linked with the internal digital signals by entering the
selection figure of the internal signal in the corresponding subcode of C0415.
C0415 can be different for the parameter sets.
Signal linkage