Operation with rated power (normal operation)
Rated data for mains voltage 400 V
4
Technical data
4.3
4.3.2
L
4.3-5
EDS82EV903-1.0-11/2002
4.3.2 Rated data for mains voltage 400 V
Typical motor p ower
P
r
[kW] 0.55 0.75 1.5 2.2
Three-phase
C asynchronous motor
(4 pole)
P
r
[hp] 0.75 1.0 2.0 3.0
8200 vector type EMC filter
integrated
E82EV551K4C0xx
6)
E82EV751K4C0xx
6)
E82EV152K4C0xx
6)
E82EV222K4C0xx
6)
Without EMC filter E82EV551K4C2xx E82EV751K4C2xx E82EV152K4C2xx E82EV222K4C2xx
Mains voltage U
mains
[V] 3/PE AC 320 V - 0 % ... 550 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply U
DC
[V] DC 450 V - 0 % ... 775 V + 0 %
Data for op eration with 3/PE AC 400 V or DC 565 V
Rated mains current
without mains choke I
mains
[A] 2.5 3.3 5.5 7.3
with mains choke I
mains
[A] 2.0 2.3 3.9 5.1
Output power U, V, W S
r
[kVA] 1.3 1.7 2.7 3.9
Output power +U
G
,-U
G
2)
P
DC
[kW] 0.3 0.1 1.1 0.4
Rated output current at 2kHzsin
chopper frequency
4kHzsin
I
r
[
]
1.8 2.4 4.7 5.6
8kHzsin I
r
[A] 1.8 2.4 3.9 5.6
16 kHz sin
4)
I
r
[A] 1.2 1.6 2.5 3.6
Max. permissible 2kHzsin
output current for 60 s
4kHzsin
I
max
[
] 2.7 3.6 5.9 8.4
at chopper frequency
3)
8kHzsin I
max
[A] 2.7 3.6 5.9 8.4
16 kHz sin
4)
I
max
[A] 1.8 2.4 3.8 5.5
Output voltage
without mains choke U
M
[V] 3~ 0 ... V
mains
/ 0 ... 650 H z
with mains choke U
M
[V] 3~ 0 ... approx. 94 % U
mains
/ 0 ... 650 H z
Power loss (operation with I
r8
) P
v
[W] 50 60 100 130
Required mains choke Type - - - -
Required brake resistor
6)
Type ERBM470R100W ERBM370R150W ERBM240R200W
Dimensions H x W x D [mm] 180 x 60 x 140 240 x 60 x 140
Weight m[kg] 1.2 1.6
Printed in bold = Data for operation at 8 kHz chopper frequency (Lenze setting)
2)
For operation with power-adapted motors additional power to be t aken from the DC bus
3)
Currents for periodic load change: 1 min overcurrent with I
max
and 2 min basic load with 75 % I
r
4)
Chopper frequency is reduced to 4 kHz if Ï‘
max
reaches - 5 °C
5)
Possible for other types with different application conditions: Operation with increased rated output current and
the same load change
(¶ 4.4-4)
6)
Operation at mains voltages 484 V - 0 % ... 550 V + 0 % is only permissible with brake resistor!