Operation with rated power (normal operation)
Rated data for mains voltage 400 V
4
Technical data
4.3
4.3.2
L
4.3-6
EDS82EV903-1.0-11/2002
Typical motor p ower
P
r
[kW] 3.0 4.0 5.5 7.5 11
Three-phase
C asynchronous motor
(4 pole)
P
r
[hp] 4.1 5.4 7.5 10.2 15
8200 vector type EMC filter
integrated
E82EV302K4C0xx E82EV402K4C0xx E82EV552K4C0xx E82EV752K4C0xx E82EV113K4C0xx
1)
Without EMC filter E82EV302K4C2xx E82EV402K4C2xx E82EV552K4C2xx E82EV752K4C2xx E82EV113K4C2xx
1)
Mains voltage U
mains
[V] 3/PE AC 320 V - 0 % ... 550 V + 0 % ; 45 Hz - 0 % ... 65Hz + 0 %
Alternative DC supply U
DC
[V] DC 450 V - 0 % ... 775 V + 0 %
Data for op eration with 3/PE AC 400 V or DC 565 V
Rated mains current
without mains choke I
mains
[A] 9.0 12.3 16.8 21.5 -
with mains choke I
mains
[A] 7.0 8.8 12.0 15.0 21.0
Output power U, V, W S
r
[kVA] 5.1 6.6 9.0 11.4 16.3
Output power +U
G
,-U
G
2)
P
DC
[kW] 1.7 0.8 1.1 1.5 0
Rated output current at 2kHzsin
chopper frequency
4kHzsin
I
r
[
]
7.3 9.5 13.0 16.5 23.5
8kHzsin I
r
[A] 7.3 9.5 13.0 16.5 23.5
16 kHz sin
4)
I
r
[A] 4.7 6.1 8.4 10.7 13.0
Max. permissible 2kHzsin
output current for 60 s
4kHzsin
I
max
[
] 11.0 14.2 19.5 24.8 35.3
at chopper frequency
3)
8kHzsin I
max
[A] 11.0 14.2 19.5 24.8 35.3
16 kHz sin
4)
I
max
[A] 7.0 9.1 12.6 16.0 19.5
Output voltage
without mains choke U
M
[V] 3~ 0 ... V
mains
/ 0 ... 650 H z
with mains choke U
M
[V] 3~ 0 ... approx. 94 % U
mains
/ 0 ... 650 H z
Power loss (operation with I
r8
) P
v
[W] 145 180 230 300 410
Required mains choke Type - - - - ELN3-150H024
Dimensions H x W x D [mm] 240 x 100 x 140 240 x 125 x 140
Weight m[kg] 2.9 3.6
Printed in bold = Data for operation at 8 kHz chopper frequency (Lenze setting)
1)
Operation only with mains choke
2)
For operation with power-adapted motors additional power to be t aken from the DC bus
3)
Currents for periodic load change : 1 min overcurrent with I
max
and 2 min basic load with 75 % I
r
4)
Chopper frequency is reduced to 4 kHz if Ï‘
max
reaches - 5 °C
5)
With different application conditions for other types possible: Operation with increased rated output current and
the same load change
(¶ 4.4-4)