Operation with rated power (normal operation)
Rated data for mains voltage 400 V
4
Technical data
4.3
4.3.2
L
4.3-8
EDS82EV903-1.0-11/2002
Typical motor p ower
P
r
[kW] 45 55 75 90
Three-phase
C asynchronous motor
(4 pole)
P
r
[hp] 60 75 100 120
8200 vector type With mains filter E82EV453K4B3xx E82EV553K4B3xx E82EV753K4B3xx E82EV903K4B3xx
Without mains filter E82EV453K4B2xx
1)
E82EV553K4B2xx
1)
E82EV753K4B2xx
1)
E82EV903K4B2xx
1)
Mains voltage U
mains
[V] 3/PE AC 320 V - 0 % ... 550 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply U
DC
[V] DC 450 V - 0 % ... 775 V + 0 %
Data for op eration with 3/PE AC 400 V or DC 565 V
Rated mains current
without mains choke I
mains
[A] - - - -
with mains choke I
mains
[A] 80.0 100 135 165
Output power U, V, W S
r
[kVA] 61.7 76.2 103.9 124.7
Output power +U
G
,-U
G
2)
P
DC
[kW] 5.1 0 28.1 40.8
Rated output current at 1kHzsin
chopper frequency
2kHzsin I
r
[A]
5)
89 110 150 159
6)
4kHzsin
8kHzsin I
r
[A] 59
6)
76
6)
92
6)
100
6)
16 kHz sin
4)
I
r
[A] 46 60 67 72
1kHz
2kHz I
r
[A]
5)
89 110 150 180
4kHz
8kHz I
r
[A] 89 110 150 171
16 kHz
4)
I
r
[A] 54 77 105 108
Max. permissible 1kHzsin
output current for 60 s
2kHzsin I
max
[A] 134 165 225 238
6)
at chopper frequency
3)
4kHzsin
8kHzsin I
max
[A] 88
6)
114
6)
138
6)
150
6)
16 kHz sin
4)
I
max
[A] 69 78 87 94
1kHz
2kHz I
max
[A] 134 165 225 270
4kHz
8kHz I
max
[A] 134 165 225 221
16 kHz
4)
I
max
[A] 81 100 136 140
Output voltage
without mains choke U
M
[V] 3~ 0 ... V
mains
/ 0 ... 650 H z
with mains choke U
M
[V] 3~ 0 ... approx. 94 % U
mains
/ 0 ... 650 H z
Power loss (operation with I
r8
) P
v
[W] 1100 1470 1960 2400
Required mains choke Type ELN3-0038H085 EL N3-0027H105 ELN3-0022H130 ELN3-0017H170
Dimensions
with mains f ilter H x W x D [mm] 510 x 340 x 375 591 x 340 x 375 680 x 450 x 375
without mains filter H x W x D [ mm] 510 x 340 x 285 591 x 340 x 285 680 x 450 x 285
Weight
with mains f ilter m[kg] 60 66 112
without mains filter m[kg] 34 37 59
Printed in bold = Data for operation at 8 kHz chopper frequency (Lenze setting)
1)
Operation only with mains choke or mains f ilter
2)
For operation with power-adapted motors additional power to be t aken from the DC bus
3)
Currents for periodic load change : 1 min overcurrent with I
max
and 2 min basic load with 75 % I
rx
4)
Chopper frequency is reduced to 4 kHz if Ï‘
max
reaches - 5 °C
5)
Possible for other types with different application conditions: Operation with increased rated output current and
the same load change
(¶ 4.4-4)
6)
Operation only with automatic chopper frequency reduction (C144 = 1). Ensure not to exceed the declared
current s.