Operation with increased rated power
Rated data for mains voltage 400 V
4
Technical data
4.4
4.4.2
L
4.4-5
EDS82EV903-1.0-11/2002
Maximum motor power
P
r
[kW] 4.0 5.5 11
Three-phase
C asynchronous motor
(4 pole)
P
r
[hp] 5.4 7.5 15
8200 vector type EMC filter
integrated
E82EV302K4C0xx E82EV402K4C0xx
1)
E82EV752K4C0xx
1)
Without EMC filter E82EV302K4C2xx E82EV402K4C2xx
1)
E82EV752K4C2xx
1)
Mains voltage V
mains
[V] 3/PE A C 320 V - 0 % ... 440 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply V
DC
[V] DC 450 V - 0 % ... 625 V + 0 %
Data for op eration with 3/PE AC 400 V or DC 565 V
Rated mains current
without mains choke I
mains
[A] 10.8 - -
with mains choke I
mains
[A] 8.4 10.6 18.0
Output power U, V, W S
r
[kVA] 6.0 7.9 13.7
Output power +U
G
,-U
G
2)
P
DC
[kW] 0.7 0 0
Rated output current at 2kHzsin
chopper frequency
4kHzsin
I
r
[
] 8.7 11.4 19.8
Max. permissible
2kHzsin
output current for 60 s
at chopper frequency
3)
4kHzsin
I
max
[
] 11.0 14.2 24.8
Output voltage
without mains choke U
M
[V] 3~ 0 ... V
mains
/ 0 ... 650 H z
with mains choke U
M
[V] 3~ 0 ...approx. 94 % V
mains
/ 0 ... 650 H z
Power loss (operation with I
r8
) P
v
[W] 145 180 300
Required mains choke Type - EZN3A 0300H013 ELN3-0150H024
Dimensions H x W x D [mm] 240 x 100 140 240 x 125 x 140
Weight m[kg] 2.9 3.6
1)
Operation only with mains choke
2)
For operation with power-adapted motors additional power to be t aken from the DC bus
3)
Currents for periodic load change: 1 min overcurrent with I
max
and 2 min basic load with 75 % I
r