Operation with increased rated power
Rated data for mains voltage 400 V
4
Technical data
4.4
4.4.2
L
4.4-4
EDS82EV903-1.0-11/2002
4.4.2 Rated data for mains voltage 400 V
Maximum motor power
P
r
[kW] 0.75 1.1 3.0
Three-phase
C asynchronous motor
(4 pole)
P
r
[hp] 1.0 1.5 4.0
8200 vector type EMC filter
integrated
E82EV551K4C0xx E82EV751K4C0xx
1)
E82EV222K4C0xx
1)
Without EMC filter E82EV551K4C2xx E82EV751K4C2xx
1)
E82EV222K4C2xx
1)
Mains voltage V
mains
[V] 3/PE A C 320 V - 0 % ... 440 V + 0 % ; 45 Hz - 0 % ... 65 Hz + 0 %
Alternative DC supply V
DC
[V] DC 450 V - 0 % ... 625 V + 0 %
Data for op eration with 3/PE AC 400 V or DC 565 V
Rated mains current
without mains choke I
mains
[A] 2.9 - -
with mains choke I
mains
[A] 2.4 2.8 6.1
Output power U, V, W S
r
[kVA] 1.5 2.0 4.6
Output power +U
G
,-U
G
2)
P
DC
[kW] 0.1 0 0
Rated output current at 2kHzsin
chopper frequency
4kHzsin
I
r
[
] 2.2 2.9 6.7
Max. permissible
2kHzsin
output current for 60 s
at chopper frequency
3)
4kHzsin
I
max
[
] 2.7 3.6 8.4
Output voltage
without mains choke U
M
[V] 3~ 0 ... V
mains
/ 0 ... 650 H z
with mains choke U
M
[V] 3~ 0 ...approx. 94 % V
mains
/ 0 ... 650 H z
Power loss (operation with I
r8
) P
v
[W] 50 60 130
Required mains choke Type - EZN3A 1500H003 E82ZL22234B
Dimensions H x W x D [mm] 180 x 60 x 140 240 x 60 x 140
Weight m[kg] 1.2 1.6
1)
Operation only with mains choke
2)
For operation with power-adapted motors additional power to be t aken from the DC bus
3)
Currents for periodic load change : 1 min overcurrent with I
max
and 2 min basic load with 75 % I
r