Lenze · E84AYCER communication module (PROFINET) · EDS84AYCER EN 3.0 - 02/2019 23
Installation
Mechanical installation
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
5.1 Mechanical installation
The communication module can be plugged in or unplugged from the MCI slot when the inverter is
switched on. When the module is plugged in, it is detected automatically, and a function and versi-
on plausibility check is executed.
5.1.1 Mounting for standard devices of 0.25 kW and 0.37 kW
[5-1] Mounting for standard devices of 0.25 kW and 0.37 kW
Mounting steps
1. Use a screwdriver to lever out the cover of the MCI slot of the standard device and remove it (1,
2).
2. Loosen the securing screw for the communication module at the standard device (3).
3. Insert the communication module into the MCI slot of the standard device (4).
4. Tighten the securing screw again (5).
E84YCPM002D