Commissioning
Setting the station name
36
Lenze · E84AYCER communication module (PROFINET) · EDS84AYCER EN 3.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.3 Setting the station name
The station name currently used is shown in code C13864.
The station name ...
is required for unambiguous addressing of the Inverter Drive 8400 by the I/O controller.
can either be assigned by the I/O controller via PROFINET or set manually in the »Engineer«.
has to be allocated in accordance with the PROFINET specification:
1 or several labels separated by ".".
Max. length per label: 63 characters
Max. total length: 240 characters
Permissible characters: [a ... z], [0 ... 9], [.], [-]
Labels must not begin or end with [-].
Prohibited syntax:
"n.n.n.n" (n = 0 ... 999)
"port-xyz" (x, y, z = 0 ... 9)
"port-xyz-abcde" (a,b,c,d,e,x,y,z=0...9)
Note!
The "Node blinking test" PROFINET function by means of which an accessible device
can be identified is supported. During execution of the function, the red LED ME
(Module status displays
( 74)) blinks.
Operation on the PROFINET requires a valid station name.
In the case of impermissible settings, the red BE (Fieldbus status displays
( 75)) blinks
and the error message PROFINET: Station name error [0x01bc6532]
( 83) is output.
The communication module then continues to work internally with the name deleted.
If the station name is assigned by the IO controller via PROFINET or the PROFINET con-
figurator of the »Engineer«, changes will be effective immediately.