Data transfer
47 Lenze · E84AYCER communication module (PROFINET) · EDS84AYCER EN 3.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
7 Data transfer
PROFINET transmits parameter data, configuration data, diagnostic data, alarm messages, and pro-
cess data between the host system (IO controller) and the inverters that are part of the fieldbus (I/
O devices). As a function of their time-critical behaviour, the data are transmitted via corresponding
communication channels.
Communication channels
The process data channel transmits process data.
The process data serve to control the inverter.
The transmission of process data is time-critical.
Process data are transmitted cyclically between the I/O controller and the I/O devices that are
part of the fieldbus according to the Provider/Consumer model (continuous exchange of cur-
rent input and output data).
The I/O controller can directly access the process data. In the PLC, for instance, the data are
directly assigned to the I/O area.
Inverter Drives 8400 allow for a maximum of 16 process data words (16 bits/word) to be ex-
changed for each direction.
Process data are not saved in the inverter.
Process data are e.g. setpoints, actual values, control words, and status words.
Parameter data are transmitted via the acyclic channel.
The transmission of parameter data is usually not time-critical.
The access to the parameter data depends on the PROFIdrive profile.
Examples of parameter data are operating parameters, motor data, and diagnostic informa-
tion.
The acyclic channel provides access to all Lenze codes.
Parameter data changes must be saved via code C00002 of the Inverter Drives 8400.
Note!
Please observe the direction of the flow of information!
Process input data (Rx data):
Process data from the inverter (IO device) to the IO controller
Process output data (Tx data):
Process data from the IO controller to the inverter (IO device)