Parameter data transfer
Error information (error)
68
Lenze · E84AYCER communication module (PROFINET) · EDS84AYCER EN 3.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
9.4 Error information (error)
Error code Meaning Description Additional in-
formation
0x0000 Impermissible parameter
number
Access to unavailable parameter -
0x0001 Parameter value cannot be
changed
Change access to a parameter value that cannot be
changed
Subindex
0x0002 Lower or upper value limit ex-
ceeded
Change access with value beyond the value limits Subindex
0x0003 Faulty subindex Access to unavailable subindex Subindex
0x0004 No array Access with subindex to non-indicated parameter -
0x0005 Wrong data type Change access with value that does not match the
data type of the parameter
-
0x0006 No setting permitted (only
resettable)
Change access with value unequal to 0 where this is
not permitted
Subindex
0x0007 Description element cannot
be changed
Change access to a description element that cannot
be changed
Subindex
0x0008 Reserved (PROFIdrive profile V2: PPO-Write requested in the IR
is not available)
-
0x0009 Description data not availab-
le
Access to unavailable description (parameter value is
available)
-
0x000A Reserved (PROFIdrive profile V2: Wrong access group) -
0x000B No parameter change rights Change access without parameter change rights -
0x000C Reserved (PROFIdrive profile V2: Wrong password) -
0x000D Reserved (PROFIdrive profile V2: Text in the cyclic traffic can-
not be read)
-
0x000E Reserved (PROFIdrive profile V2: Name in the cyclic traffic can-
not be read)
-
0x000F No text array available Access to unavailable text array (parameter value is
available)
-
0x0010 Reserved (PROFIdrive profile V2: Missing PPO-Write) -
0x0011 Request cannot be executed
due to the operating state
Access is not possible due to temporary reasons not
specified here
-
0x0012 Reserved (PROFIdrive profile V2: Other error) -
0x0013 Reserved (PROFIdrive profile V2: date in the cyclic traffic can-
not be read)
-
0x0014 Value impermissible Change access with the value that is inside the value
limits but not permissible for other permanent re-
asons (parameters with defined individual values)
Subindex
0x0015 Response too long The length of the current response exceeds the maxi-
mum transmittable length
-
0x0016 Parameter address imper-
missible
Impermissible or non-supported value for attribute,
number of subindices, parameter number, or subin-
dex, or a combination
-
0x0017 Format impermissible Write request: Impermissible or non-supported for-
mat of parameter data
-
0x0018 Number of values not consis-
tent
Write request: Number of values of the parameter
data do not match the number of subindices in the
parameter address
-
0x0019 Reserved - -
...
0x0064