EasyManua.ls Logo

Lenze E84AYCER - Detailed Error Causes and Remedies

Lenze E84AYCER
101 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Lenze · E84AYCER communication module (PROFINET) · EDS84AYCER EN 3.0 - 02/2019 81
Error messages
Possible causes and remedies
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
12.2 Possible causes and remedies
In this chapter, all error messages of the communication module are listed in numerical order of the
error numbers. Possible causes and remedies and responses to the error messages are described in
detail.
Tip!
You will find a list of all error messages of the communication module in alphabetical order
in the previous chapter "Short overview of the PROFINET error messages
" ( 80).
PROFINET: Exist. conn. to 8400 lost [0x01bc3100]
PROFINET: Memory: No access [0x01bc5531]
PROFINET: Memory: Read error [0x01bc5532]
PROFINET: Memory: Write error [0x01bc5533]
Response (Lenze setting printed in bold) Setting: not possible
No reaction System fault Fault Trouble Quick stop by trouble WarningLocked Warning Information
Cause Remedy
MCI communication to Inverter Drive 8400 is interrup-
ted.
Inverter Drive 8400 is switched off.
The communication module is not connected correct-
ly at the MCI slot of the Inverter Drive 8400.
Switch on Inverter Drive 8400.
Check screwed connection of the communication mo-
dule at the MCI slot of the Inverter Drive 8400.
Send the communication module and Inverter Drive
8400 together with a description of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
No reaction System fault Fault Trouble Quick stop by trouble WarningLocked Warning Information
Cause Remedy
Access to memory was not possible. Send communication module together with a descripti-
on of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
No reaction System fault Fault Trouble Quick stop by trouble WarningLocked Warning Information
Cause Remedy
Parameter could not be read. Send communication module together with a descripti-
on of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
No reaction System fault Fault Trouble Quick stop by trouble WarningLocked Warning Information
Cause Remedy
Parameter could not be written. Send communication module together with a descripti-
on of the fault to Lenze.

Table of Contents

Other manuals for Lenze E84AYCER

Related product manuals