Error messages
Possible causes and remedies
82
Lenze · E84AYCER communication module (PROFINET) · EDS84AYCER EN 3.0 - 02/2019
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
PROFINET: Restart by watchdog reset [0x01bc6010]
PROFINET: Internal error [0x01bc6011]
PROFINET: Internal error [0x01bc6100]
PROFINET: Internal error [0x01bc6101]
PROFINET: Invalid parameter set [0x01bc641f]
PROFINET: Error: Lenze setting loaded [0x01bc6420]
Response (Lenze setting printed in bold) Setting: not possible
No reaction System fault Fault Trouble Quick stop by trouble WarningLocked Warning Information
Cause Remedy
Communication module is defective. Send communication module together with a descripti-
on of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
No reaction System fault Fault Trouble Quick stop by trouble WarningLocked Warning Information
Cause Remedy
Communication module is defective. Send communication module together with a descripti-
on of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
No reaction System fault Fault Trouble Quick stop by trouble WarningLocked Warning Information
Cause Remedy
Internal error Send communication module together with a descripti-
on of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
No reaction System fault Fault Trouble Quick stop by trouble WarningLocked Warning Information
Cause Remedy
Internal error Send communication module together with a descripti-
on of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
No reaction System fault Fault Trouble Quick stop by trouble WarningLocked Warning Information
Cause Remedy
No active parameter set could be loaded. • Download application again (including module).
• Send communication module together with a de-
scription of the fault to Lenze.
Response (Lenze setting printed in bold) Setting: not possible
No reaction System fault Fault Trouble Quick stop by trouble WarningLocked Warning Information
Cause Remedy
Access to parameter set in the memory module was not
possible.
• Download application again (including module).
• Send device with error description to Lenze.