8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00090
186 L Firmware 03.00 - DMS EN 5.0 - 07/2009
C00090
C00091
C00092
C00093
C00094
C00095
Parameter | Name:
C00090 | Rated motor voltage
Data type: UNSIGNED_16
Index: 24485
d
= 5FA5
h
This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor
catalogue, the suitable value can be entered automatically.
Setting range (min. value | unit | max. value) Lenze setting
0 V 1000 400 V
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 1
Parameter | Name:
C00091 | Motor cosine phi
Data type: UNSIGNED_8
Index: 24484
d
= 5FA4
h
This value can be obtained from the motor nameplate. After the motor to be used has been selected from the motor
catalogue, the suitable value can be entered automatically.
Setting range (min. value | unit | max. value) Lenze setting
0.40 1.00 0.85
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 100
Parameter | Name:
C00092 | Motor magnetizing inductance
Data type: UNSIGNED_16
Index: 24483
d
= 5FA3
h
After the motor to be used has been selected from the motor catalogue, the suitable value can be entered automat-
ically. An automatic detection via the motor parameter identification is possible as well.
Setting range (min. value | unit | max. value) Lenze setting
0.0 mH 6500.0 0.0 mH
; Read access ; Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 10
Parameter | Name:
C00093 | Power section ID
Data type: UNSIGNED_16
Index: 24482
d
= 5FA2
h
Display of the identification of the detected power section of the frequency inverter
Display range (min. value | unit | max. value)
0 65535
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00094 | Password
Data type: INTEGER_32
Index: 24481
d
= 5FA1
h
The controller provides the opportunity to protect the menu level from unauthorised access by assigning a pass-
word.
Password protection
Setting range (min. value | unit | max. value) Lenze setting
0 9999 0
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00095 | Motor magnetising current
Data type: UNSIGNED_16
Index: 24480
d
= 5FA0
h
From version 03.00.00
After the motor to be used has been selected from the motor catalogue, the suitable value can be entered automat-
ically. An automatic detection via the motor parameter identification is possible as well.
Display range (min. value | unit | max. value)
0.00 A 99.00
; Read access Write access CINH PLC STOP No transfer COM ; MOT Scaling factor: 100