Firmware 03.00 - DMS EN 5.0 - 07/2009 L 195
8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00159
C00159
C00165
C00166
C00167
Parameter | Name:
C00159 | Cause of quick stop QSP
Data type: UNSIGNED_16
Index: 24416
d
= 5F60
h
Bit coded display of the cause/source of quick stop
Display range (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded:
Bit 0 Terminal
Bit 1 Reserved
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Application
Bit 5 Controller command
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00165 | Error information
Data type: VISIBLE_STRING
Index: 24410
d
= 5F5A
h
Display of the error numbers divided into sectors in the case of an error
Subcodes Info
C00165/1 Current error
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00166 | Error information text
Data type: VISIBLE_STRING
Index: 24409
d
= 5F59
h
Display of details on the currently pending error
Subcodes Info
C00166/1 Resp. - current error
Response of the currently pending error
C00166/2 Subj. - current error
Subject area of the currently pending error
C00166/3 Mess. - current error
Textual message of the currently pending error
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00167 | Logbook data
Data type: OCTET_STRING
Index: 24408
d
= 5F58
h
This code is used internally by the controller and must not be overwritten by the user!