Parameter reference
Parameter list | C00170
C00170
C00171
C00173
C00174
C00177
Parameter | Name:
C00170 | Error counter
Data type: UNSIGNED_8
Index: 24405
d
= 5F55
h
Display of the error counter for the 8 errors occurred last
Display range (min. value | unit | max. value)
0 255
Subcodes Info
C00170/1 Error counter - history 1
C00170/2 Error counter - history 2
C00170/3 Error counter - history 3
C00170/4 Error counter - history 4
C00170/5 Error counter - history 5
C00170/6 Error counter - history 6
C00170/7 Error counter - history 7
C00170/8 Error counter - history 8
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00171 | Logbook access index
Data type: UNSIGNED_8
Index: 24404
d
= 5F54
h
This code is used internally by the controller and must not be overwritten by the user!
Parameter | Name:
C00173 | Mains voltage
Data type: UNSIGNED_8
Index: 24402
d
= 5F52
h
Selection of the mains voltage for operating the device.
Selection list (Lenze setting printed in bold) Info
0 3ph 400V / 1ph 230V 3-phase 400 V or 1-phase 230 V
1 3ph 440V / 1ph 230V 3-phase 440 V or 1-phase 230 V
2 3ph 480V / 1ph 230V 3-phase 480 V or 1-phase 230 V
3 3ph 500V / 1ph 230V 3-phase 500 V or 1-phase 230 V
; Read access ; Write access ; CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00174 | Reduced brake chopper threshold
Data type: UNSIGNED_8
Index: 24401
d
= 5F51
h
The threshold from which on the brake chopper is controlled is reduced by the voltage value set here.
Setting range (min. value | unit | max. value) Lenze setting
0 V 150 0V
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00177 | Switching cycles
Data type: UNSIGNED_32
Index: 24398
d
= 5F4E
h
Counter of different switching cycles and stressful situations
Display range (min. value | unit | max. value)
0 2147483647
Subcodes Info
C00177 /1 Number of mains switching cycles
C00177 /2 Number of the switching cycles of the output relay
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1