Parameter reference
Parameter list | C00178
198 L Firmware 03.00 - DMS EN 5.0 - 07/2009
C00178
C00179
C00182
C00200
C00201
C00203
Parameter | Name:
C00178 | Elapsed-hour meter
Data type: UNSIGNED_32
Index: 24397
d
= 5F4D
h
Display of the operating hours in "seconds" unit"
Display range (min. value | unit | max. value)
0 s 2147483647
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00179 | Power-on time meter
Data type: UNSIGNED_32
Index: 24396
d
= 5F4C
h
Display of the power-on time in "seconds" unit"
Display range (min. value | unit | max. value)
0 s 2147483647
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00182 | S-ramp time PT1
Data type: INTEGER_16
Index: 24393
d
= 5F49
h
PT1 S-ramp time for the main setpoint ramp function generator
Only effective with activated ramp rounding (C00134
="1").
Setting range (min. value | unit | max. value) Lenze setting
0.01 s 50.00 20.00 s
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00200 | Firmware product type
Data type: VISIBLE_STRING
Index: 24375
d
= 5F37
h
Display of the firmware product type
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00201 | Firmware compile date
Data type: VISIBLE_STRING
Index: 24374
d
= 5F36
h
Display of the firmware compilation date
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00203 | Product type code
Data type: VISIBLE_STRING
Index: 24372
d
= 5F34
h
From version 03.00.00
Display of the single device component types
Subcodes Info
C00203/1 Reserved
C00203/2 Reserved
C00203/3 Reserved
C00203/4 Reserved
C00203/5 Type: Memory module
C00203/6 Type: Safety module
C00203/7 Reserved
C00203/8 Type: Complete device
C00203/9 Reserved
; Read access Write access CINH PLC STOP ; No transfer COM MOT