Firmware 03.00 - DMS EN 5.0 - 07/2009 L 189
8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00118
C00118
C00120
C00123
C00134
Parameter | Name:
C00118 | DOx inversion
Data type: UNSIGNED_8
Index: 24457
d
= 5F89
h
Polarity of the digital outputs
Every digital output of the device can be inverted with regard to polarity via this bit field.
I/O terminals
Setting range (min. hex value | max. hex value) Lenze setting
0x00 0xFF 0x00 (decimal: 0)
Value is bit-coded: (; =bit set) Info
Bit 0 Relay inverted Relay inversion
Bit 1 DO1 inverted Inversion of digital output 1
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
; Read access ; Write access CINH PLC STOP No transfer COM MOT
Parameter | Name:
C00120 | Motor overload threshold (I²xt)
Data type: INTEGER_16
Index: 24455
d
= 5F87
h
Operating threshold for the error message "OC6: Motor overload (I²xt)"
The response for reaching the threshold can be selected in C00606
.
The current thermal motor load is displayed in C00066
.
Setting range (min. value | unit | max. value) Lenze setting
0 % 250 100 %
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00123 | Device utilisat. threshold (Ixt)
Data type: INTEGER_16
Index: 24452
d
= 5F84
h
Operating threshold for the error message "OC5: Device overload (Ixt)"
The response for reaching the threshold can be selected in C00604
.
The current device utilisation is displayed in C00064
.
Setting range (min. value | unit | max. value) Lenze setting
0 % 100 100 %
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00134 | Ramp smoothing main setpoint
Data type: UNSIGNED_8
Index: 24441
d
= 5F79
h
Configuration of the ramp rounding for the main setpoint
Selection list (Lenze setting printed in bold) Info
0Off Ramp rounding deactivated
1 PT1 behaviour Ramp rounding with PT1 behaviour
The corresponding S-ramp time must be set in
C00182
.
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1

Table of Contents