EasyManua.ls Logo

Lenze L-force 8400 BaseLine D - Page 203

Lenze L-force 8400 BaseLine D
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 03.00 - DMS EN 5.0 - 07/2009 L 203
8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00444
C00444
C00470
Parameter | Name:
C00444 | DOx: Level
Data type: UNSIGNED_16
Index: 24131
d
= 5E43
h
Bit coded display of the level of the digital outputs
I/O terminals
Display range (min. hex value | max. hex value)
0x0000 0xFFFF
Value is bit-coded: Info
Bit 0 Relay Bit set = HIGH level
Bit 1 DO1
Bit 2 Reserved
Bit 3 Reserved
Bit 4 Reserved
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
Bit 8 Reserved
Bit 9 Reserved
Bit 10 Reserved
Bit 11 Reserved
Bit 12 Reserved
Bit 13 Reserved
Bit 14 Reserved
Bit 15 Reserved
Subcodes Info
C00444/1 DOx: Input level
C00444/2 DOx: Terminal level
; Read access Write access CINH PLC STOP ; No transfer COM MOT
Parameter | Name:
C00470 | LS_ParFree_b
Data type: UNSIGNED_8
Index: 24105
d
= 5E29
h
SB LS_ParFree_b: Setting of the signal level to be output
Selection list
0False
1True
Subcodes Lenze setting Info
C00470/1 0: False Signal level for output bPar1 ... bPar16
C00470/...
C00470/16
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1