EasyManua.ls Logo

Lenze L-force 8400 BaseLine D - Page 205

Lenze L-force 8400 BaseLine D
228 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Firmware 03.00 - DMS EN 5.0 - 07/2009 L 205
8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00482
C00482
C00516
Parameter | Name:
C00482 | LS_DisFree_a
Data type: INTEGER_16
Index: 24093
d
= 5E1D
h
SB LS_DisFree_a: Display of the input values
Display range (min. value | unit | max. value)
-199.9 % 199.9
Subcodes Info
C00482/1 Input values nDis1_a ... nDis4_a
C00482/...
C00482/4
; Read access Write access CINH PLC STOP No transfer COM MOT Scaling factor: 100
Parameter | Name:
C00516 | Checksums
Data type: UNSIGNED_32
Index: 24059
d
= 5DFB
h
Display range (min. value | unit | max. value)
0 255
Subcodes Info
C00516/1 Checksum of the interconnection
; Read access Write access CINH PLC STOP ; No transfer COM MOT Scaling factor: 1

Table of Contents