EasyManua.ls Logo

Lenze L-force 8400 BaseLine D - Page 206

Lenze L-force 8400 BaseLine D
228 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8400 BaseLine D | Software Manual
Parameter reference
Parameter list | C00517
206 L Firmware 03.00 - DMS EN 5.0 - 07/2009
C00517
C00565
C00574
Parameter | Name:
C00517 | User menu
Data type: INTEGER_32
Index: 24058
d
= 5DFA
h
When a system is installed, parameters must be changed time and again until the system runs satisfactorily. The
user menu of a device serves to create a selection of frequently used parameters to be able to access and change
these parameters quickly.
Setting range (min. value | unit | max. value)
0 994
Subcodes Lenze setting Info
C00517/1 51 C00051
: Display of actual speed value
C00517/2 53 C00053
: Display of DC-bus voltage
C00517/3 54 C00054
: Display of motor current
C00517/4 61 C00061
: Display of heatsink temperature
C00517/5 137 C00137
: Display of device state
C00517/6 0
C00517/7 0
C00517/8 11 C00011
: Reference speed
C00517/9 39 C00039
: Fixed setpoints 1 ... 3
C00517/10 0
C00517/11 12 C00012
: Accel. time - main setpoint
C00517/12 13 C00013
: Decel. time - main setpoint
C00517/13 15 C00015
: V/f base frequency
C00517/14 16 C00016
: Vmin boost
C00517/15 22 C00022
: Imax in motor mode
C00517/16 120 C00120
: Motor overload threshold (I
2
xt)
C00517/17 87 C00087
: Rated motor speed
C00517/18 99 C00099
: Display of firmware version
C00517/19 0
C00517/20 0
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00565 | Resp. to mains phase failure
Data type: UNSIGNED_8
Index: 24010
d
= 5DCA
h
Response to the failure of mains phases
Selection list (Lenze setting printed in bold)
0 No Reaction
1Fault
4 WarningLocked
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1
Parameter | Name:
C00574 | Resp. to brake resist. overtemp.
Data type: UNSIGNED_8
Index: 24001
d
= 5DC1
h
Response to overtemperature of the brake resistor
Selection list (Lenze setting printed in bold)
0No Reaction
1Fault
4 WarningLocked
; Read access ; Write access CINH PLC STOP No transfer COM MOT Scaling factor: 1

Table of Contents