4-4 Service Manual
5022-xxx
2. Remove the paper exit tray for access to the printhead alignment screw (B).
3. Enter Diagnostic mode (turn off the printer, press and hold and , turn on the printer, and release the
buttons when the clock graphic displays).
4. Select REGISTRATION.
5. Select Skew.
6. Adjust this setting to zero, and press Select ( ).