4-92 Service Manual
5022-xxx
Transfer contact assembly removal
See “Transfer contact assembly” on page 7-11 for the part number.
1. Remove the HVPS. See High voltage power supply (HVPS) removal” on page 4-62.
2. Remove all the inside contact springs. See “Contact springs removal” on page 4-44.
3. Remove the four screws (A), and remove the transfer contact assembly.
4. Remove the eight springs (B) for reuse during installation.
Note: The top spring may fall away from the transfer contact assembly during removal.
Installation note: For ease of installation, put the transfer contact assembly on before installing the springs.
B
B
B
A
A