1-4 Service Manual
5022-xxx
Environment
Acoustics
All measurements are made in accordance with ISO 7779 and conform with ISO 9296.
Environment Specifications
Operating
Air Temperature—Product Operating 15.6 to 32.2° C (60 to 90.0° F)
Air Temperature—Product Power Off 10.0 to 40.0° C (50 to 104.0° F)
Air Relative Humidity Relative Humidity 8 to 80%
Wet Bulb Temperature—Product Operating 22.8° C (73.0° F) Maximum
Web Bulb Temperature—Product Power Off 26.7° C (80.1° F) Maximum
Altitude 0 to 3048 meters (10,000 feet)
Atmospheric Pressure 74.6 kPa
Ambient Operating Environment
†
15.6 to 32.2° C (60 to 90°F) and 8% to 80% RH
Shipping / Storage
Cartridges -40° C to +40° C (104° Fahrenheit)
Printer with Cartridges -40° C to +40°C (104° Fahrenheit)
Printer without Cartridges -40° C to +40°C (104° Fahrenheit)
Air Relative Humidity Relative Humidity 8 to 80%
Altitude 10,300 meters (34,000 feet)
Web Bulb Temperature—Product Power Off 26.7° C (80.1° F) Maximum
†
In some cases performance specifications (such as paper OCF, EP cartridge usage) are specified to be
measured at an ambient condition.
Printer Operating mode
1-Meter Average
Bystander Sound
Pressure @4800 CQ
Declared Sound
Power Level @4800
CQ
C520n, C522n, C524n
Printing 51 dBA
Idle 32 dBA
C524dn, C524dtn
Printing 51 dBA
Duplex printing 52 dBA
Idle 32 dBA
C532n, C534n
Mono printing 53 dBA 6.7B
Color printing 51 dBA 6.6B
Idle 31 dBA 4.6B
C530dn, C534dn, C534dtn
Mono printing 53 dBA 6.7B
Color printing 51 dBA 6.6B
Duplex printing 53 dBA 6.7B
Idle 31 dBA 4.6B