Repair information 4-37
5022-xxx
Bin full sensor removal—models C52x
See “Bin full sensor with cable, C520n/C522n/C524n/C524dn” on page 7-3 for the part number.
1. Open the top access door.
2. Remove the fuser. See “Fuser removal” on page 4-60.
3. Disconnect the spring (A).
4. Remove the seven screws (B) securing the inner access cover.
5. Remove the inner access cover.
6. Turn the access cover over, and press the back of the sensor to snap sensor (C) from the bracket.
7. Remove the sensor and cable.