159
Error Codes
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG” is a registered trademark of LG Corp.
ERROR CODES
Please refer to the Safety Precautions on pages 4-7 for more detail to prevent injury or death regarding the operation and service
troubleshooting of the Multi V product.
WARNING
Error No. 40
Error No. Description Details Causes
40
Master: 401
Slave 1: 402
Slave 2: 403
Outdoor unit
inverter com-
pressor current
transducer (CT)
sensor error.
Disconnection or short circuit of outdoor
unit inverter compressor current detection
(CT) sensor.
MICOM input voltage is not within 2.5V
±0.3V at initial power up.
1. Input voltage is not correct (T-S).
2. Damaged DC power component (DC 5V).
3. Outdoor unit inverter PCB is damaged (CT
sensor component).
Are the power wiring connec-
tions correct?
Recheck power and installation.
1. Check R(L1) / S(L2) / T(L3) wiring connec-
tions.
2. Check noise filter wiring connections.
ĺ5HZLUHLIHUURUVDUHIRXQG
No
Yes
Yes
Is the input voltage normal?
Is the inverter compressor PCB
assembly correct?
Yes
No
No
Check if R~S / S~T / T~R phase voltage is
208-230V ±10%, or within the 414-528V range
for 460V.
ĺ&KHFNZLUHVDQGFRQQHFWLRQVLISRZHULVQRW
correct.
Replace inverter compressor PCB assembly.
Measure input voltage.
Inverter compressor PCB assembly.
Images here are representative
of system components. Actual
component appearance depends
on model and system type.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the LG Multi V5 and is the answer not in the manual?

LG Multi V5 Specifications

General IconGeneral
Compressor TypeInverter Scroll
RefrigerantR410A
Energy EfficiencyHigh
Heat RecoveryAvailable
Smart DiagnosisYes
TypeVRF (Variable Refrigerant Flow)
ControlCentralized Control
Power Supply380-415V / 3Ph / 50Hz