INSTALLATION & SERVICE MANUAL – FLEXSTEP V2– UK VERSION
1.7
Liftup A/S Hagensvej 21| DK-9530 Støvring | Denmark | T: +45 96 86 30 20 | M: support@liftup.dk | www.liftup.dk | CVR DK-1015 3964
5.3 Setting virtual top stop by “Service Mode”
When the system is in service mode (see 6.1) it is possible to set the virtual top stops.
1. Set the system into service mode.
2. Push the emergency button, (Push and hold the on-board UP & DOWN buttons,
release the emergency button while holding the UP & DOWN buttons for 15
seconds.
3. Move the platform down to the lower level, to make sure that the system is
calibrated.
4. Push the “lift up” button, until the desired level is reached.
5. Push the emergency button, and push the on-board UP-button to set Platform Lifting
Height and push the on-board DOWN-button to set the Stair Position. (Sound
will confirm, when height is programmed)
(As all lifts are with 2 stops, you have to program both, before leaving the Service
Mode)
6. Leave service mode, Push the emergency button, (Push and hold the on-board UP &
DOWN buttons. Release the emergency button while holding the on-board UP &
DOWN buttons for 15 seconds.)