INSTALLATION & SERVICE MANUAL FLEXSTEP V2 UK VERSION
1.7
Liftup A/S Hagensvej 21| DK-9530 Støvring | Denmark | T: +45 96 86 30 20 | M: support@liftup.dk | www.liftup.dk | CVR DK-1015 3964
5
1.2 Unpacking and moving the product
The FlexStep V2 is equipped with batteries so even if the power supply is not connected
to the lift, the lift can move (not the case if its prepared for disassembly). To start
moving the FlexStep V2 you need to make some changes on the Safety Circuit of the
product as it is by default delivered with all safety functions active.
Remove the 3 screws on the top of the Primary Control Unit (Right Hand Side of the
product). Remove the cover and slide the cover upwards to remove it.
Once done, you see the Primary Control Unit.
In order to move the product, place a jumper on:
- Upper Gate SW
- Under Pan SW
If you now release the emergency button, you should have all green LED’s on (see
photo).