 MMX8x4-HT series – User's Manual 140



or until the clear() method is called.
Command and Response
ç <loc>.RxHex
æ <loc>

Example
ç 
æ 
Clearing the Last Recognized Stored Message
Rx, RxHex and Hash properties.
Command and Response
ç <loc>:clear()
æ <loc>:clear
Example
ç 
æ 

temporaryActiveTimeout
property is elapsed, the property is cleared.
TIPS AND TRICKS: 
follow each other, the action will execute every occasion. (A Condition can be detected in Event Manager if
a change happens. In this case, the string is stored in the property and after the ActiveTimeout it will be
cleared. If the same string is saved into the (empty) property that will cause a change.)
Command and Response
ç <loc>.ActiveRx
æ pr<loc>
Parameters
The 
Example
ç 
æ 
INFO: Please note that the property contains the string until the ActivePropertyTimeout is elapsed only.

Command and Response
ç <loc>.ActiveRxHex
æ <loc>

Parameters
The 
Example
ç 
æ 
INFO: Please note that the property contains the data until the ActivePropertyTimeout is elapsed only.
Set the Active Timeout
This property is responsible for clearing the ActiveRx, ActiveRxHex, ActiveHash properties after the elapsed
time. Default value is 50ms.
Command and Response
ç <loc><a_timeout>
æ <loc><a_timeout>
Parameters
The <a_timeout> parameter is the active timeout value (ms) between 0 and 255.
Example
ç 
æ 
Running an Immediate Event Action


Command and Response
ç <loc><event_nr>
æ <loc><event_nr>
Parameters
The <event_nr> means the number (location) of the linked Event Action without letter 'E'. (There is no need
