EasyManua.ls Logo

Lightware MX16x16DVI-Plus - Read an Inputs Name; Read an Outputs Name; Reload Default Preset Names; Reload Default Input Names

Lightware MX16x16DVI-Plus
89 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 58 / 89 Section 8. Programmers reference
8.4.17. Read an input’s name
Format
Example
Command
{INAME#<id>=?}
{iname#3=?}
Response
(INAME#<id>=
<input_name>)CrLf
(INAME#3=MEDIA PLAYER)CrLf
Explanation: Name for input 3 is “media player”.
8.4.18. Read an output’s name
Format
Example
Command
{ONAME#<id>=?}
{oname#2=?}
Response
(ONAME#<id>=
<output_name>)CrLf
(ONAME#2=MONITOR_NO2)CrLf
Explanation: Name for output 2 is “monitor_no2”.
Set default names of Presets / Inputs / Outputs
Description: Renames all preset / input / output names to the default: Preset 1..32 / Input
1..16 / Output 1..16 respectively.
Info: The <id> field is not relevant here, only has to be a valid one. The command will affect ALL
Presets / Inputs / Outputs disregarding the actual number that was in the command.
8.4.19. Reload default preset names
Format
Example
Command
{PNAME#<id>=!}
{pname#2=!}
Response
(PNAME#<id>=
Preset<id>)CrLf
(PNAME#2=Preset 2)CrLf
Info: Preset names will be renamed to the factory defaults but will not refreshed in the Lightware
Device Controller software. Please click on the Read preset names button to refresh all
the preset names.
8.4.20. Reload default input names
Format
Example
Command
{INAME#<id>=!}
{iname#4=!}
Response
(INAME#<id>=
Input<id>)CrLf
(INAME#4=Input 4)CrLf
Info: Input names will be renamed to the factory defaults but will not refreshed in the Lightware
Device Controller software. Please right click on one input name and choose the Read I/O
names item to refresh all the input names.

Table of Contents