112
7. Calibrate (by measurement using loopback path 3) the control value of the RBANK
(ladder only) for the 5.5MHz bandwidth setting => Register the value of the RBANK
controls.
8. Adjust the value of the real pole controls by -50% (pre-emphasis/real pole RBANK).
9. Calibrate (by measurement using loopback path 4) the mismatch between the pre-
emphasis and the real pole stage. => Register the ‘low’ pre-emphasis parameters.
(5.5MHz).
10. Calibrate (by measurement using loopback path 5) the control value of the RBANK
(ladder only) for the 2.74MHz bandwidth setting => Register the value of the RBANK
controls.
11. Calibrate (by measurement using loopback path 5) the control value of the RBANK
(ladder only) for the 2.4MHz bandwidth setting => Register the value of the RBANK
controls.
12. Restore configuration