Chapter 1: Alarms
QUICK SIX
1-21
A048 – Safety Time for Part Feed Out
SAFETY TIME
FOR PART FEED OUT
ELAPSED!
POSSIBLE CAUSES:
-PROGRAMMING ERROR
-MECH. INTERFERENCE
-INTERFACE PROBLEM
A048
Description:
The Safety Time For Part Feed Out Elapsed alarm occurs if the value set in OVERALL PART LENGTH is not reached within 1 minute
after the bar feed is commanded to feed out.
Solution:
Alarm needs to be cleared. Press the STOP key on the remote control station to clear the message and reset the alarm.
Make sure that value for the OVERALL PART LENGTH is correct.
Check for any mechanical obstruction that will not allow the bar feed to reach the feed out distance.
Contact LNS America, Inc. for further information.