1-22 Chapter 1: Alarms
QUICK SIX
A049 – Measuring Cell SQ@ is Activated too Early
MEASURING CELL SQ@
IS ACTIVATED TOO
EARLY!
POSSIBLE CAUSES:
- BAR STOCK EXCEEDS
MAXIMUM SAFETY
LENGTH
- BAR STOCK LIMITERS
NOT IN CORRECT
LOCATION A049
Description:
The Measuring Cell SQ@ is Activated Too Early alarm occurs during the loading cycle if input signal (I0.7 – SQ1) turns on too early.
Solution:
Verify that the length of the bar that was loaded should not exceed 6’4”.
The pusher is not cut to proper length or does not correspond to the “Length of Feeding Pusher.”