ZENIT
35
BASE SETTINGS
Pilot Spindles
At a yarn change (Adjust) the yarn reference value of the first
80 m of yarn are measured and stored with the pilot spin-
dles. Each winding place of the group can be used as pilot
spindle.
Define at least 10% of the spindles of every group as pilot
spindles. For groups of 10 spindles or less, select at least
two pilot spindles.
Data Acquisition
Mode
Last With the Last setting, the current data of a group or
spindle are indicated for the last 100 km, for example.
First With the First setting, the detection of monitor-
ing and classification data of the current production is
stopped at e.g. 100 km Window Length (selectable). This
would mean for a group of 50 spindles that the first 2 km
of every spindle are displayed together. With 1000 m/min
spindle speed, 100 km are reached in 2 min.
Cone With the Cone setting, the data of each individ-
ual cone will be shown in the Monitoring Data and Class
Data menus and automatically deleted after changing.
The current data of the group are displayed for the last
e.g.100 km (Window Length).
Window Length
In Window Length, the observation length can be selected
between 10 –1000 km.
Reset Data
Under Reset Data the stored Monitoring Data and Class Data can
be erased. (The shift data are retained.)
•
Activate Reset.
•
Enter Yes in the message box “RESET Monitoring Data and
Class Data ?”.