EasyManua.ls Logo

Loepfe YarnMaster Zenit - Setting Examples (Standard Values)

Default Icon
83 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
50
ZENIT
YARN STRUCTURE
Setting Examples (Standard Values)
Channel
Cotton and blended yarns short-staple
Insensitive setting N=6 DS=2.6 LS=1.6
DL=1.32 LL=60 -D=29% -L=70
Sensitive setting N=5.5 DS=2.2 LS=1.4
DL=1.26 LL=50 -D=22% -L=50
Very sensitive setting N=4.5 DS=2.1 LS=1.3
DL=1.20 LL=40 -D=17% -L=32
Long-staple yarns
Insensitive setting N=6 DS=2.6 LS=2.3
DL=1.30 LL=60 -D=30% -L=70
Sensitive setting N=6 DS=2.2 LS=2.0
DL=1.22 LL=50 -D=23% -L=60
Very sensitive setting N=5.5 DS=1.9 LS=2.5
DL=1.19 LL=45 -D=18% -L=60
Splice
Sensitive setting N=OFF DS=2.2 LS=1.6
DL=1.30 LL=12 -D=OFF -L=70
CheckLen Splice = 25 cm
Very sensitive setting N=OFF DS=2.2 LS=1.3
DL=1.25 LL=12 -D=20% -L=70
CheckLen Splice = 25 cm
SFI / D
Insensitive setting Limit +/– 30%
Sensitive setting Limit +/– 25%
Very sensitive setting Limit +/– 20%
VCV
Insensitive setting Limit +/– 30%
Length
50 m
Sensitive setting Limit +/– 25%
Length
20 m
Very sensitive setting Limit +/– 20%
Length
10 m
Cluster Short / Long / Thin
Possible setting
Short
Long Thin
Diameter DS 1.34
DL 1.12 -D -8%
Length
LS 1.60 cm
LL 16 cm -L 16 cm
Obs. Length 20 m
12 m 12 m
Faults 55
25 25
If, at the Observation Length of 20 m, the number of Faults is exceeding 55,
the respective spindle will be blocked.
Setting for detection of a defective top roller:
Diameter DS 1.33
Length LS 1.30
Obs. Length
20 m
Faults 170

Table of Contents