ZENIT
CONFIGURATION
Configuration
Basic system settings.
System
CheckLen Splice
Yarn length with which the splice check is performed after
a cut or after a restart. The splice check length is automat-
ically set to 25 cm. It can be changed to a value between
0 and 120 cm.
Set CheckLenSplice to 0 cm to deactivate the splice check.
Total Spindles
Enter the number of installed spindles for this machine.
Headstock
Input of machine head location: Left or right.
Alarm Display
Selection of alarms to be displayed in a message box.
None No alarms are displayed
All All alarms are displayed
Technical Only the technical alarms are displayed:
System Alarm, Offline, etc.
Textile Only the “textile” alarms are displayed:
Off Count, Cluster, etc.
The respective error messages are displayed in the Dialog
menu under Reports.
Yarn Count
The yarn numbering system (Nm, Nec, New, Tex, Den) is
selectable.