ZENIT
41
BASE SETTINGS
Display TK
It can be defined what the TK is to display after a cut/spindle
start. (See also “7-Segment Display”, page 77)
Default settings are marked with an asterisk (*).
!
If required, these settings should be altered by in-
structed personnel only!
* Cut/Alarm Type
All textile yarn cuts and the corresponding cut alarms.
* Count Difference +/– 5%
A yarn diameter deviation of more than +/– 5% is displayed:
—
Deviation smaller than +/– 5%
—
Deviation more than – 5%
—
Deviation more than + 5%
* Programstate Special
System Info :
A Adjust is running
d Doffing (cone change)
S Start signal standby (during Power On)
P Parameter standby (during StartUp)
* Technical Alarm
Alternating display of technical alarms :
A / 1 alternating Knife short-circuit
A / 3 alternating NTP signal line interruption
A / 4 alternating Knife blocking
A / 5 alternating Transfer alarm