ZENIT
45
YARN STRUCTURE
!
Faults / Observation Length
These two settings define the limits of the accumulation den-
sity to the length unit for the faults which are above the clus-
ter curve.
When the set number of faults is exceeded within the set ob-
servation length, the spindle is blocked after the set number
of repetitions.
Act. Faults
All events (irregularities) above the cluster curve are continu-
ously count ed via the set Window Length (Base Settings menu).
The number obtained in this manner is converted to the ob-
servation length and displayed as setting support in Act. Faults.
The set number of faults must be signifi cantly
higher than the displayed events (Act. Faults).
If the number of counted events is 10% higher
than the set number of faults, cluster cuts can oc-
cur more frequently. (If necessary, increase the
«Diameter» value).
Diameter
Yarn diameter setting range:
Short (DS) 1.10 – 4.00
Long (DL) 1.04 – 2.00
Thin (-D) - 6% – - 60%
The setting range refers to the normal yarn diameter. For ex-
ample, if the same setting is chosen as for the channel set-
ting (DS / DL / -D), it corresponds to the normal clearing curve
set. The number 1.0 would correspond to the base, viz. the
normal yarn diameter.
Length
Reference length setting range:
Short (LS) 1.0 cm – 10 cm
Long (LL) 6.0 cm – 200 cm
Thin (-L) 2.0 cm – 200 cm