2. Operation 27
2. Press Enter and Next to go to menu 4B) Sensor Calibration.
3. Press Enter to go to the password page.
4. Use Back, Next, Up, and Down to enter the user password, and then press Enter to go to
4B1) Automatic Value Calibration Wizard.
5. Press Enter to go to 4B1A).
6. Use Back and Next to select the length sensor, and then press Enter to confirm communica-
tion with the sensor is possible.
7. Press Next to start the wizard.
8. Note the units that will be used during the calibration wizard, and then press Next.
9. Fully retract the boom, and then press Next.
10. Use Up and Down to adjust the length value displayed to equal the actual fully retracted boom
length, and then press Next.
11. Fully extend the boom, and then press Next.
12. Use Up and Down to adjust the length value displayed to equal the actual fully extended boom
length, and then press Next.
13. Note the new trim value, and then press Next.
14. Note the new scale value, and then press Next.
15. Press Enter to send the new calibration to the length sensor.
16. Press Exit three times to return to the operation display.