363-206-295
Administration and Provisioning
Issue 1 December 1997 8-17
Table 8-2 throughTable 8-9 list the various types of supported cross-connections.
Following the tables are descriptions of applications and the cross-connections
each application requires.
Table 8-2. DDM-2000 OC-12 Manual STS-1 Cross-Connections (Termination).
Table 8-3. DDM-2000 OC-12 Manual STS-3c Cross-Connections (Termination).
From To “To” CP Type Example Command *
mb-{1-12} <--> a-{1-3} 3STS1E, 3DS3, OLIU ent-crs-sts1:mb-1,a-1
mb-{1-12} <--> b-{1-3} 3STS1E, 3DS3, OLIU ent-crs-sts1:mb-2,b-3
mb-{1-12} <--> c-{1-3} 3STS1E, 3DS3, OLIU ent-crs-sts1:mb-3,c-2
mb-{1-12} <--> d-{1-3} 3STS1E, 3DS3, OLIU ent-crs-sts1:mb-4,d-2
∗ Cross-connection type is not entered because default is twoway.
From To “To” CP Type Example Command *
mb-{1,4,7,10} <--> a-1 21-type OLIU ent-crs-sts3c:mb-1,a-1
mb-{1,4,7,10} <--> b-1 21-type OLIU ent-crs-sts3c:mb-4,b-1
mb-{1,4,7,10} <--> c-1 21-type OLIU ent-crs-sts3c:mb-7,c-1
mb-{1,4,7,10} <--> d-1 21-type OLIU ent-crs-sts3c:mb-10,d-1
∗ Cross-connection type is not entered because default is twoway.