EasyManuals Logo

Lucent Technologies DDM-2000 OC-12 User Manual

Lucent Technologies DDM-2000 OC-12
1676 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #401 background imageLoading...
Page #401 background image
363-206-295
Technical Specifications
10-30 Issue 1 December 1997
Equipment Indicators 10
A red LED FAULT indicator is provided on all circuit packs. A green LED ACTIVE
indicator is provided on all 1x1 protected circuit packs to indicate which circuit
packs are actively carrying traffic.
Office Alarms 10
The office alarms interface is a set of discrete relays that control office audible and
visual alarms. Separate relays handle CR, MJ, and MN alarms. Each contact
closure is rated at 1 A, 60 V, maximum. The CR and MJ alarms can be wire-
ORed. The CR alarm relays are fail-safe against unprotected power failures.
User-Definable Miscellaneous Discretes—
Environmental Alarms and Controls 10
The user-definable miscellaneous discrete environmental alarm and control
interface allows the DDM-2000 OC-12 Multiplexers to monitor and control
equipment at the local site. Twenty-one alarm or status environmental inputs can
monitor environmental conditions (for example, open door, high temperature);
these inputs are activated by contact closures. The 15th environmental alarm or
status input is provided to monitor the condition of the power shelf and fans; this
closure is activated by 48 V DC. Four environmental control outputs are provided
to control external equipment (for example, pumps or generators). The
miscellaneous discrete outputs (control outputs, alarm/status outputs) tolerate
60 V maximum open circuit voltage and 35 mA maximum current. Transient
voltages up to 135 V are tolerated for up to 1 ms. The miscellaneous discrete
inputs (control inputs at a CO) provide 48 V nominal (60 V maximum) open
circuit voltage and 2 mA maximum current. The miscellaneous discrete output
closures generated by the optoisolator require external voltage and ground to
operate.
The 21 alarm or status inputs can be reported through a TL1/X.25 interface.

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-12

Questions and Answers: