4.1 Test Run Simple Mode
To test the feeding process with the four sets of IR trigger sensors in the bill path.
4.1.1 Run Value List
To check the gap adjustment by using the retrieved values.
1. Choose a desired speed for testing.
2. Change the solenoid to Downposition.
3. Start Run Value List
by pressing the “ after
selecting on the item.
4. Place a bundle of 50 pcs test notes
(Denomination: 1USD) on the hopper and pull the
hopper guide to fix the size of test note. The
machine starts running once it detects notes on
the hopper.
Note: The distance of two sides from hopper to banknote
shall be around 3mm to 5 mm.
5. Once notes proceed, sensors retrieve value and
they are showed on the list.
MAX: Value of Tilt shall not over 4.
AVE: Value of Tilt shall not over 2.
QTY: Value of L shall not less than 10.
Value of IN Cnt and OUT Cnt shall be 50.
*Note: Repeat the same process FIVE times and the result
should be similar. If two or more test results are not under
acceptable range, please adjust the gap and test.