Service Manual NC-6000 Date: OCT 1
st
, 2012 (Version 1.0)
Masterwork Automodules Tech. Corp., Ltd
Confidential
- 25 -
4.5.4 Calibraiton of Hopper Sensor
To calibrate the IR hopper sensor.
1. Highlight the option and press “ to enter the
burn in mode.
2. Press “ to calibrate the hopper sensor.
3. Once a green mark appears beside the option, the
calibration is completed successfully.
4. Highlight the option “Exit” and press ” to go back
to the upper layer.
Note: In order to calibrate hopper sensor, the status of Hpr
Ttrigger Detection Mode(Under the opiton Setup
DeviceParameters) shall be in Ver2. To setup the Hpr
Detection Mode, refer to page 32.
4.6 Test Device
To test the functionalities of all the parts and to make sure the stability of machine.
4.6.1 Solenoid
To test the reaction time of solenoid.
1. Highlight the option and press “ key.
2. Solenoid toggles between UP and DOWN to
stacker pocket and the display shows a speed.