Service Manual – NC-6000 Date: OCT 1
st
, 2012 (Version 1.0)
Masterwork Automodules Tech. Corp., Ltd
Confidential
- 55 -
1. Loosen the two screws (M3x5-Countersunk
2. Loosen the screws (M3x5-Countersunk) on the both sides
of the hopper.
3.
Release the ground cable by loosening the screw
(M3x6-Rround Head with spring washer).
4. Disconnect the cables on the PCB board.
5. The control panel module is removed from the machine.
5.3.2.1 PCB NC6000-UI Board
1. Turn the control panel module to the rear side.
2. Release the tenon of control panel assembly from the
control panel plate.