4.6.2 Machine Running Status
Testing the machine for basic running status under different speeds.
1. Set a preferred speed for testing the device.
2. Different speed can be set by press “ ” key: 600,
650, 700, 750, 800, 1000, 1200, Min and Max.
*Raise the “sub singler roller” to segregate the sound of
vibration when the motor is running.
3. Highlight the option and press “ key.
4. Check if the rollers run well to test the functionality
of front motor.
5. Highlight the option and press “ key.
6. Highlight the option Motor Run” and press “
key.
7. Motor starts running.
*Note: The option “Motor Run” changes to “Motor Stop”.
8. Once confirming all works well, Highlight the option
“Motor Stop” and press “ key.
9. A number of Encoder is showed on the right side of
the “Motor Run”
10. Switch motor speed and repeat the test process
with each speed.
(600→650→700→800→1000→1200→Min→Max→6
00)
*If the motors run with strange noise during the test, please
contact MA.
Sub singler