Service Manual NC-6000 Date: OCT 1
st
, 2012 (Version 1.0)
Masterwork Automodules Tech. Corp., Ltd
Confidential
- 48 -
5.3.1.2 PCB NC6100-S board
1. Release the cables from the connecters.
*Note: When plugging in the cable on the connecters,
please make sure all the pins are well connected on the
cable.
2. Loosen the four screws (Ø3x8-Round Head
) on the
PCB-S board.
3. Pull up straightly the PCB-S board.
4. The PCB-S board is removed from the upper bill path
module.
5.3.1.3 PCB NC6100-IRTE Board
1. Pull up the NC6100-IRTE board.