The machine counts and the solenoid toggles between
reject pocket and stacker. Check the two pockets to
make sure that banknote are separated equally in both
pockets.
*Note: If the Solenoid &Break doesn’t function well, please
contact MA.
4.2 Test Run Strict Mode
To test the feeding process with 128 pairs IR array and the four sets of IR trigger
sensors in the bill path.
4.2.1 Run Value List
To check the gap adjustment by using the retrieved values.
1. Choose a desired speed for testing.
2. Change the solenoid to “Down” position.
3. Start “Run Value List
” by pressing the ” after
selecting on the item.
4. Place a bundle of 50 pcs test notes
(Denomination: 1USD) on the hopper and pull the
hopper guide to fix the size of test note. The
machine starts running once it detects notes on
the hopper.
Note: The distance of two sides from hopper to the edge of
banknote shall be around 3mm to 5 mm.