Service Manual – NC-6000 Date: OCT 1
st
, 2012 (Version 1.0)
Masterwork Automodules Tech. Corp., Ltd
Confidential
- 47 -
5.3.1.1 Upper Bill Path Plate
1. Turn the upper bill path module and have the sensor
side down.
2. Loosen the three screws (Ø3x8-Round Head) to
release the ground cables.
3. Loosen the two screws (Ø3x8-Round Head) on the both
sides.
*Note: When assembling the upper bill path plate with
retarding wheel module, please make sure the space
between the wheel module and the plastic.
4. The upper bill path plate is removed from the retarding
wheel module.