EasyManua.ls Logo

Mahr MarSurf RD 18 User Manual

Mahr MarSurf RD 18
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Mahr GmbH · Carl-Mahr-Straße 1 · D-37073 Göttingen · Telefon +49 551 7073-0 · Fax +49 551 71021
Operating Instructions
MarSurf M 300 + RD 18

Table of Contents

Questions and Answers:

Mahr MarSurf RD 18 Specifications

General IconGeneral
Measuring PrincipleInductive
Resolution8 nm
Probe Tip Radius2 µm
Measuring Force0.75 mN
Storage Temperature-20°C to 70°C
Resolution (nm)8 nm
Resolution (µm)0.008 µm
Power SupplyBattery or mains

Summary

Safety Instructions

General Safety Precautions

Covers reading documentation, specific use, avoiding hazards, and proper handling.

1 Functions

Evaluation

Describes how measured profiles are analyzed and evaluated using various parameters.

2 Operating Elements

3 Commissioning

3.3 Charging the Battery

Instructions for charging the internal batteries of the MarSurf M 300 and RD 18.

3.5 Making Instrument Settings

Procedures for configuring instrument parameters and standards.

3.5.2 Basic Settings

Covers selecting standards, managing timeout functions, and blocking settings with a code.

Measuring and Evaluation Conditions

3.5.3 ISO, ASME, JIS Conditions

Details measurement and evaluation conditions according to ISO, ASME, and JIS standards.

3.5.4 MOTIF Conditions

Details measurement and evaluation conditions according to the MOTIF standard.

3.5.5 Parameters and Tolerance Limits

How to select parameters and set tolerance limits for evaluation.

Programming Function Keys (F1/F2)

How to assign functions to the programmable F1 and F2 keys.

4 Preparing for Measurement

4.1 Setting up Mobile Measuring Station

Steps to set up the instrument for mobile operation.

4.2 Setting up Stationary Measuring Station

Guide for mounting and setting up the instrument for stationary use.

4.3.2 Selecting Pick-up Type (Meas. Range)

Procedure to select the correct pick-up type and its measuring range.

4.3.3 Setting up Bluetooth Connection

Steps to establish a wireless Bluetooth connection between devices.

5 Measurement and Evaluation

5.1 Measurement

Instructions for performing surface texture measurements with the instrument.

5.2 Evaluation

Describes how to interpret and analyze measurement results.

5.3 Available Parameters

Lists all parameters that can be calculated and evaluated by the instrument.

5.4 Saving Profiles

Guide on how to save measured profiles to the internal USB memory.

5.5 Saving Measuring Results

Instructions for saving measurement results and sequences.

6 Calibrating and Setting Pick-up Correction Value

6.1 Setting Pick-up Correction Value

How to manually enter a correction value for the pick-up.

7 Troubleshooting

9 Maintenance, Cleaning and Transport

Related product manuals