OPERATING PROCEDURES GRT655/655L OPERATOR MANUAL
4-64 Published 3-23-2020, Control # 654-04
When a limitation is active, the warning buzzer inside the cab
will sound. Table 4-4 indicates the behavior of the warning
buzzer for the various limitations.
Table 4-4 Alarm Characteristics
LIMITATION POSITION ALARM
Height Limitation 10 ft before limit Slow beeping
5 ft before limit Fast beeping
At limit Constant sound
Boom Angle 10 deg before limit Slow beeping
5 deg before limit Fast beeping
At limit Constant sound
Radius 10 ft before limit Slow beeping
5 ft before limit Fast beeping
At limit Constant sound
Swing 20 deg before limit Slow beeping
5 deg before limit Fast beeping
At limit Constant sound
Virtual wall 20 ft before limit Slow beeping
5 ft before limit Fast beeping
At limit Constant sound