National Crane 03-20-2019 Control # 613-06 3-15
NBT30H-2 SERVICE MANUAL ELECTRIC SYSTEM
Table 3-7
13 Truck Fault Yellow J1939 Truck Fault
14 Truck Fault Red J1939 Truck Fault
15 Inability to log FLASH sector undefined
16 Inability to log FLASH write failure
17 Cleared by user (via RCL display) Cleared FLASH sectors
18 E-Stop CAN and input
19 Bus Traffic\Error CAN Status
20 EEPROM Update Update Fail: EEPROM Selected Out of Range
21 EEPROM Update Update Fail: New EEPROM Value Out of Range
22 EEPROM Update Update Fail
23 RCL Override Key Error Console override key active during remote mode
Error # Error Description Error Source
Device Group Index Error Pin, Wire, Description Possible Causes/Comments
19
1
31 18 A02, 343, SYSTEM ESTOP
E-Stop input and remote module CAN message are
not in agreement (CAN is in E-Stop, input is not)
19 1 44 23
A01, 72, Console RCL
Override Key
Console override key activated during remote
operation mode
19 2 32 11
A07, 1813, PS FRONT
BEAM POTENTIOMETER
String Pot sensor value is above
OR_PS_Front_Full_Extend EEPROM value (+
OMS_Adc_Tolerance + OMS_Adc_High) in RCL
Module
19 2 32 12
A07, 1813, PS FRONT
BEAM POTENTIOMETER
String Pot sensor value is below
OR_PS_Front_Min_Extend EEPROM value (-
OMS_Adc_Tolerance - OMS_Adc_High) in RCL
Module
19 2 33 11
A08, 1814, DS FRONT
BEAM POTENTIOMETER
String Pot sensor value is above
OR_DS_Front_Full_Extend EEPROM value (+
OMS_Adc_Tolerance + OMS_Adc_High) in RCL
Module
19 2 33 12
A08, 1814, DS FRONT
BEAM POTENTIOMETER
String Pot sensor value is below
OR_DS_Front_Min_Extend EEPROM value (-
OMS_Adc_Tolerance - OMS_Adc_High) in RCL
Module
19 2 34 11
B05, 1815, PS REAR BEAM
POTENTIOMETER
String Pot sensor value is above
OR_PS_Rear_Full_Extend EEPROM value (+
OMS_Adc_Tolerance + OMS_Adc_High) in RCL
Module
19 2 34 12
B05, 1815, PS REAR BEAM
POTENTIOMETER
String Pot sensor value is below
OR_PS_Rear_Min_Extend EEPROM value (-
OMS_Adc_Tolerance - OMS_Adc_High) in RCL
Module
19 2 35 11
B06, 1816, DS REAR
BEAM POTENTIOMETER
String Pot sensor value is above
OR_DS_Rear_Full_Extend EEPROM value (+
OMS_Adc_Tolerance + OMS_Adc_High) in RCL
Module